1.0 SYSTEM SELECTION

1.01 GENERAL

1.01.1. Thousands of possible combinations of polymer resins, curing agents and aggregates are available for use in epoxy flooring systems. Each combination offers a different balance of performance properties, so it is essential that the designer prioritize performance requirements when selecting materials for a particular flooring application. This section contains sample performance profiles for three different types of epoxy coating and topping systems:

a. Flexible modified epoxy for crack bridging, impact absorption, and application over substrates with high deflection or vibration.

b. Semi-rigid Bisphenol A epoxy for general purpose floor topping and coating.

c. Novolac/Bisphenol F epoxy for applications under more severe chemical exposure or higher temperature.

1.01.2. It should be recognized that many factors must be weighed in selecting the particular materials for any specific application, and that many other types of epoxy systems are available to meet specialized needs. But the three basic types, above, provide the tools required for achieving most flooring objectives. In cases involving special requirements, the designer should consult with a technical specialist for additional options.

1.02 SELECTION FACTORS

The following is a partial list of factors to weigh in designing/selecting a polymer surfacing system:

a. Aesthetics (Check One)

Color granule pattern

Solid color coating in color(s) as selected by Owner’s representative

Clear finish

b. Texture/Safety Flooring system shall be designed for compliance with OSHA requirements:

40-60 mesh fine quartz texture for light anti-slip finish in pedestrian traffic areas

28 mesh color granule anti-slip surface where decorative anti-slip finish is required.

12-20 mesh coarse finish for pneumatic tire vehicular traffic in wet areas

Surfaces subject to extreme heavy traffic and abrasion shall be textured with aluminum oxide.

Untextured (Dry areas)

c. Flexibility High flexibility is required in some areas, especially around drains & at coved bases so movements, temperature changes & impacts won’t crack or chip the surface. Flexibility is also required to reduce tendency for subsurface cracks to transmit to the surface, causing it to crack. In addition, some structures undergo high vibration or deflection and require a more flexible system to prevent cracking. If the floor develops surface cracks or chips, contamination can be drawn into the matrix or into the subsurface causing further deterioration and an unsanitary environment. Rigid systems are required for higher chemical resistance, higher scratch resistance, and to efficiently transmit loads to the rest of the structure in situations where the system has a structural role, such as in repair of columns, structural slabs and piers.

d. Chemical resistance is the ability of the floor system to withstand exposure to cleaning compounds, water, or other materials being handled in the particular subject environment. Knowledge of the particular chemicals to which the floor system will potentially be exposed, as well as their concentrations and temperatures is a critical factor in proper floor system design.

e. Pitch, or the need to slope the floor toward drains so that cleaning and rinsing water doesn’t stand and allow bacteria to breed, will help determine whether a trowel-grade mortar must be installed as part of the flooring system. Sloping with concrete is less expensive than sloping with epoxy mortar, and is preferred when under new construction, but in restoration work the time delay for concrete curing (28 days) may not be possible.

f. Coved bases at wall/floor joints are required in sanitary areas such as food processing plants or laboratory animal rooms so that contamination doesn’t stand in corners or at edges of floor.

g. Structural: Maximum expected service load must be calculated, and flooring system design capacity should be at least three times this anticipated maximum or as otherwise required by State and local building codes. This includes evaluation of not only the type of traffic (heavy vs. light) expected, but also subfloor strength, its structural supports, all static and dynamic loads, as well as the strength of the epoxy composition floor system itself. In renovation or restoration projects, the condition of the substrate and the need for any structural repairs must be considered.

h. Heat: Most standard Bisphenol A epoxies soften at 110-160F. Service exposures in excess of this range require the use of harder, higher temperature resistant epoxies, such as epoxy novolacs.

i. Thermal Shock: Rapid temperature change creates stresses which must be considered in a number of applications, including:

-Coolers & freezers

-Floors which will be hot water washed or steam cleaned regularly

-Floors near heat-releasing equipment which operates intermittently, such as batch dryers and ovens

-Exterior applications subject to wide temperature swings

j. Sanitation/Permeability While surface texture also impacts on ease of cleaning, permeability is the single most important factor affecting both sanitation and rates of deterioration of surfacing systems and concrete subsurfaces. The ratio of the polymer to aggregate/filler is the most important factor in achieving a non-porous, impenetrable surfacing system.

k. Environmental Requirements Volatile Organic Compounds content (V.O.C.) is regulated in many areas by law, and industrial maintenance coatings must comply with the maximum allowable solvent content where so regulated. Odors pose other potentially serious problems in both new construction and renovation work, as personnel detecting typical solvent and some polymer odors are likely to protest a perceived hazardous material exposure, even if exposure levels are below the permissable OSHA limits. Odorless or low odor systems should be specified wherever exposure of non-installer personnel is likely.

l. Aggregates: Aggregates/Fillers are initially important for reducing stress caused by the resin/hardener polymerization reaction and the heat released by that reaction. After the reaction, aggregates/fillers contribute to thickness, texture, appearance and abrasion resistance. The following aggregates are commonly used:

Quartz: High purity silica sand in various particle size ranges.

Colored Quartz: Silica particles with colored coating, usually in 12 or 28 mesh sizes, used for their decorative appearance in combination with clear resin while providing non-slip texture.

Aluminum oxide/ carborundum: Harder than quartz, used for non-slip texture and high abrasion resistance in heavy abrasive environments.

Glass beads, walnut shells, metallics: Special purpose aggregates for increasing light reflectance or other special purpose applications.

m. Thickness/Film Build

The number and types of coatings used will determine overall system build or thickness. Some common types include:

Sealer (Primer): 5-10 mils thickness, used for penetration into concrete to bond subsequent layer, to prevent dusting, or to prevent vapor transmission

Coating — with optional anti-slip aggregate: 10-50 mils thickness, for use as a thin layer of protective surfacing or as a topcoat in a composition system (topping).

Topping: 50-250 mils thickness, used for the following applications:

-High traffic with turning

-High impact resistance

-Thermal shock resistance

-Maximum chemical resistance

-Color pattern & texture variations

-Maximum durability

1.03 DEFINITIONS

Polymer — Resinous synthetic material used as the binder in a protective coating or the matrix of a composition surfacing system, e.g. epoxy, polyurethane, MMA, polyester, etc.

Polymer/Aggregate Ratio — Ratio of the amount of polymer (resin plus curing agent; liquid components) to the amount of aggregate/filler by volume (coarse aggregates, fine fillers and extenders). This is the most useful factor in designing non-porous, impermeable surfacing systems. Note: Another way to specify the polymer/aggregate ratio: No more than 25 lbs. aggregate to no less than one gallon epoxy (liquid components) covering no more than 25 sq. ft. area at 1/8 thick (or 17 sq. ft. area at 3/16 thick).

Polymer Composition Surfacing (Topping) — System consisting of a primer/sealer, possible underlayment, matrix of polymer & aggregate/filler, and a coating (topcoat).

Coverage Rate — Relates amount of a particular component or composition used for a unit area, e.g. sq.ft./gal. It is important to distinguish between coverage rates for liquid components only and the coverage rate for a mixture composed of the coating, aggregates and fillers.

Aggregate/Filler — Organic & inorganic particles and/or fibers added to polymer liquid components to produce a matrix composition.

Liquid Components — Polymer resin and curing agent, which must be mixed together at a prescribed Mix Ratio. Ratios of resin to hardener are usually expressed by volume, to facilitate field measurement.

Sealer (Primer) — Generally solvent thinned polymer applied 5-10 mils thick

Coating — Generally 90-100% solids polymer with some fillers & pigments applied at 10-50 mils thickness.

Topping — Composition surfacing consisting of coating material and additional aggregate/filler, applied at 50-250 mils thickness, i.e. mortar, slurry, broadcast.

Resin Rich — High polymer/aggregate ratio method of installing composition flooring systems that achieve maximum impermeability and performance characteristics.

1.04 PRODUCTS

A distinction is to be made between individual components or materials used in the flooring system and the composite system assembled to meet a project’s aesthetic and functional requirements. The polymer composition special surfacing system is composed of several materials or components, utilized for specific functions within the system.

1.04.1. SPECIFICATION FOR EPOXY QUARTZ COMPOSITION FLOORING SYSTEM

a. Epoxy composition flooring system shall be a resin rich composite consisting of:

1. Low viscosity clear epoxy primer, for maximum bond potential.

2. 100% solids epoxy mortar underlayment for cracked, spalled or depressed area patching; for sloping & pitching to drains; for forming cove bases; for sealing around drains 100% solids resin rich epoxy mortar matrix layer with high polymer to aggregate ratio for thickness & texture

3. Two 100% solids topcoats for final seal and texture

b. Primer (Subsurface conditions dictate the selection of an appropriate primer. Check one of the following.)

1. Highly polished, dense concrete shall be primed using a water or solvent thinned 30% solids epoxy with chemical coupling agent additive designed to promote chemical bond to bare concrete.

2. Worn, spalled, very porous concrete shall be primed using 100% solids epoxy primer.

3. Bonding to oil saturated concrete, after chemically removing as much contamination as possible and mechanically abrading, shall be enhanced by utilizing a special oil tolerant, 100% solids modified epoxy primer

4.Damp subsurfaces shall be primed for adequate adhesion, when time won’t permit thorough drying, with waterborne or moisture insensitive epoxy primer. This technique must be limited to applications which will not result in encapsulation of moisture in concrete or the creation of negative side hydrostatic force behind the epoxy composition flooring system.

5. Very smooth, non-porous subsurfacing, such as glazed tile, shall be prepared for excellent adhesion by first treating with a ceramic etch compound and then priming with epoxies that contain additional wetting agents and chemical coupling agents.

c. Special Polymer Underlayments

The following special purpose polymer underlayments shall be used as applicable. (Check all that apply.)

__100% solids elastomeric epoxy membrane and underlayment with long term flexibility shall be used to provide waterproofing of small working cracks, and to act as a stress relieving / stress absorbing base coat between substrate and flooring, and to enhance bond potential. 100% solids elastomeric epoxy mortar shall be used for patching, joint nosing repair, for forming wall/floor intersecting coved base radius and for filler around drain housings (see accompanying detail sketches). Polymer to aggregate ratio shall be 1:2 by weight.

__Expansion joint treatment: See accompanying detail sketches.

__Pitching and sloping shall be performed using semi-rigid, 100% solids epoxy combined with graded, high density quartz aggregate with polymer to aggregate ratio of 1 to 4 by weight. At perimeter of the room where thicker section of mortar is required, the polymer to aggregate can be lowered to 1 to 6 and the matrix can be extended with larger, pea gravel aggregate.

__Thin section pitching mortar — from 2 to feather edge — shall be prepared using higher polymer to aggregate ratios with smaller aggregates. See accompanying detail sketches.

NOTE: If the floor surfacing system requires pitching or sloping, first prime the subsurface, do all patching, crack repair, & drain detail work, then install pitching & sloping mortar, then install 100% solids elastomeric epoxy layer, then proceed with the matrix (body) layer

d. Matrix Layer

Matrix layer shall be prepared using semi-rigid, 100% solids, cycloaliphatic amine cured epoxy with standard grade 28 mesh quartz (or colored quartz for multi-color pattern floors). Polymer/aggregate ratio to be 1:2 by volume, which will produce the required impermeable, non-porous surface. For forming vertical surfaces use semi-rigid, 100% solids cycloaliphatic amine cured epoxy and aggregate composition with polymer/aggregate ratio of 1 to 4, or polymer/aggregate ratio of 1 to 3 with thixotropic agent such as fumed silica added to the matrix composition.

e. Topcoats

Use semi-rigid, 100% solids cycloaliphatic amine cured epoxy without aggregates or fillers. Use clear epoxy for multi-colored quartz patterns and use pigmented epoxy in color selected by Owner for solid-colored floors. Note: For rough textures, apply single topcoat 15 mils thick; for smoother textures, apply second topcoat at 10-15 mils thick For areas subjected to constant temperatures greater than 1600F, use 100% solids Novolac epoxy for the topcoat and in the matrix layer. In areas that may require greater chemical resistance, please consult with flooring system installer and manufacturer for assistance in selection of appropriate material for the specific chemical exposure.

1.04.2. PERFORMANCE CRITERIA — COMPOSITE SYSTEM

The typical performance properties listed in Tables 1-4 shall represent the minimum standards for each type of component as listed. Materials which fail to meet all of these criteria will not be acceptable for use.

1.04.3. ACCEPTABLE MANUFACTURER

The following shall be acceptable products and manufacturers, and shall be deemed to conform to the requirements of these specifications:

a. Semi-rigid 100% solids epoxy shall be FLEXI-GARD 500-S as manufactured by Edison Coatings, Inc. Plainville, CT 06704 Phone (800)697-8055.

b. 100% solids Novolac epoxy shall be FLEXI-GARD 500-N as manufactured by Edison Coatings, Inc.

c. 100% solids Flexible modified epoxy shall be FLEXI-DECK 500-E as manufactured by Edison Coatings, Inc.

d. Low temperature 100% solids flexible epoxy shall be FLEXI-DECK 500-U- LT as manufactured by Edison Coatings, Inc.

e. Oil-tolerant, low viscosity epoxy primer shall be FLEXI-DECK 500-L as manufactured by Edison Coatings, Inc.

Table 1. Typical 100% Solids, Semi-Rigid Bisphenol A Epoxy Flooring

SPECIFICATION GUIDE TO SELECTION, PREPARATION, APPLICATION AND MAINTENANCE OF EPOXY COMPOSITION SURFACING SYSTEMS

1.0 SYSTEM SELECTION

1.01 GENERAL

1.01.1. Thousands of possible combinations of polymer resins, curing agents and aggregates are available for use in epoxy flooring systems. Each combination offers a different balance of performance properties, so it is essential that the designer prioritize performance requirements when selecting materials for a particular flooring application. This section contains sample performance profiles for three different types of epoxy coating and topping systems:

a. Flexible modified epoxy for crack bridging, impact absorption, and application over substrates with high deflection or vibration.

b. Semi-rigid Bisphenol A epoxy for general purpose floor topping and coating.

c. Novolac/Bisphenol F epoxy for applications under more severe chemical exposure or higher temperature.

1.01.2. It should be recognized that many factors must be weighed in selecting the particular materials for any specific application, and that many other types of epoxy systems are available to meet specialized needs. But the three basic types, above, provide the tools required for achieving most flooring objectives. In cases involving special requirements, the designer should consult with a technical specialist for additional options.

1.02 SELECTION FACTORS

The following is a partial list of factors to weigh in designing/selecting a polymer surfacing system:

a. Aesthetics (Check One)

Color granule pattern

Solid color coating in color(s) as selected by Owner’s representative

Clear finish

b. Texture/Safety Flooring system shall be designed for compliance with OSHA requirements:

40-60 mesh fine quartz texture for light anti-slip finish in pedestrian traffic areas

28 mesh color granule anti-slip surface where decorative anti-slip finish is required.

12-20 mesh coarse finish for pneumatic tire vehicular traffic in wet areas

Surfaces subject to extreme heavy traffic and abrasion shall be textured with aluminum oxide.

Untextured (Dry areas)

c. Flexibility High flexibility is required in some areas, especially around drains & at coved bases so movements, temperature changes & impacts won’t crack or chip the surface. Flexibility is also required to reduce tendency for subsurface cracks to transmit to the surface, causing it to crack. In addition, some structures undergo high vibration or deflection and require a more flexible system to prevent cracking. If the floor develops surface cracks or chips, contamination can be drawn into the matrix or into the subsurface causing further deterioration and an unsanitary environment. Rigid systems are required for higher chemical resistance, higher scratch resistance, and to efficiently transmit loads to the rest of the structure in situations where the system has a structural role, such as in repair of columns, structural slabs and piers.

d. Chemical resistance is the ability of the floor system to withstand exposure to cleaning compounds, water, or other materials being handled in the particular subject environment. Knowledge of the particular chemicals to which the floor system will potentially be exposed, as well as their concentrations and temperatures is a critical factor in proper floor system design.

e. Pitch, or the need to slope the floor toward drains so that cleaning and rinsing water doesn’t stand and allow bacteria to breed, will help determine whether a trowel-grade mortar must be installed as part of the flooring system. Sloping with concrete is less expensive than sloping with epoxy mortar, and is preferred when under new construction, but in restoration work the time delay for concrete curing (28 days) may not be possible.

f. Coved bases at wall/floor joints are required in sanitary areas such as food processing plants or laboratory animal rooms so that contamination doesn’t stand in corners or at edges of floor.

g. Structural: Maximum expected service load must be calculated, and flooring system design capacity should be at least three times this anticipated maximum or as otherwise required by State and local building codes. This includes evaluation of not only the type of traffic (heavy vs. light) expected, but also subfloor strength, its structural supports, all static and dynamic loads, as well as the strength of the epoxy composition floor system itself. In renovation or restoration projects, the condition of the substrate and the need for any structural repairs must be considered.

h. Heat: Most standard Bisphenol A epoxies soften at 110-160F. Service exposures in excess of this range require the use of harder, higher temperature resistant epoxies, such as epoxy novolacs.

i. Thermal Shock: Rapid temperature change creates stresses which must be considered in a number of applications, including:

-Coolers & freezers

-Floors which will be hot water washed or steam cleaned regularly

-Floors near heat-releasing equipment which operates intermittently, such as batch dryers and ovens

-Exterior applications subject to wide temperature swings

Epoxy Flooring Specification Manual

j. Sanitation/Permeability While surface texture also impacts on ease of cleaning, permeability is the single most important factor affecting both sanitation and rates of deterioration of surfacing systems and concrete subsurfaces. The ratio of the polymer to aggregate/filler is the most important factor in achieving a non-porous, impenetrable surfacing system.

k. Environmental Requirements Volatile Organic Compounds content (V.O.C.) is regulated in many areas by law, and industrial maintenance coatings must comply with the maximum allowable solvent content where so regulated. Odors pose other potentially serious problems in both new construction and renovation work, as personnel detecting typical solvent and some polymer odors are likely to protest a perceived hazardous material exposure, even if exposure levels are below the permissable OSHA limits. Odorless or low odor systems should be specified wherever exposure of non-installer personnel is likely.

l. Aggregates: Aggregates/Fillers are initially important for reducing stress caused by the resin/hardener polymerization reaction and the heat released by that reaction. After the reaction, aggregates/fillers contribute to thickness, texture, appearance and abrasion resistance. The following aggregates are commonly used:

Quartz: High purity silica sand in various particle size ranges.

Colored Quartz: Silica particles with colored coating, usually in 12 or 28 mesh sizes, used for their decorative appearance in combination with clear resin while providing non-slip texture.

Aluminum oxide/ carborundum: Harder than quartz, used for non-slip texture and high abrasion resistance in heavy abrasive environments.

Glass beads, walnut shells, metallics: Special purpose aggregates for increasing light reflectance or other special purpose applications.

m. Thickness/Film Build

The number and types of coatings used will determine overall system build or thickness. Some common types include:

Sealer (Primer): 5-10 mils thickness, used for penetration into concrete to bond subsequent layer, to prevent dusting, or to prevent vapor transmission

Coating — with optional anti-slip aggregate: 10-50 mils thickness, for use as a thin layer of protective surfacing or as a topcoat in a composition system (topping).

Topping: 50-250 mils thickness, used for the following applications:

-High traffic with turning

-High impact resistance

-Thermal shock resistance

-Maximum chemical resistance

-Color pattern & texture variations

-Maximum durability

1.03 DEFINITIONS

Polymer — Resinous synthetic material used as the binder in a protective coating or the matrix of a composition surfacing system, e.g. epoxy, polyurethane, MMA, polyester, etc.

Polymer/Aggregate Ratio — Ratio of the amount of polymer (resin plus curing agent; liquid components) to the amount of aggregate/filler by volume (coarse aggregates, fine fillers and extenders). This is the most useful factor in designing non-porous, impermeable surfacing systems. Note: Another way to specify the polymer/aggregate ratio: No more than 25 lbs. aggregate to no less than one gallon epoxy (liquid components) covering no more than 25 sq. ft. area at 1/8 thick (or 17 sq. ft. area at 3/16 thick).

Polymer Composition Surfacing (Topping) — System consisting of a primer/sealer, possible underlayment, matrix of polymer & aggregate/filler, and a coating (topcoat).

Coverage Rate — Relates amount of a particular component or composition used for a unit area, e.g. sq.ft./gal. It is important to distinguish between coverage rates for liquid components only and the coverage rate for a mixture composed of the coating, aggregates and fillers.

Aggregate/Filler — Organic & inorganic particles and/or fibers added to polymer liquid components to produce a matrix composition.

Liquid Components — Polymer resin and curing agent, which must be mixed together at a prescribed Mix Ratio. Ratios of resin to hardener are usually expressed by volume, to facilitate field measurement.

Sealer (Primer) — Generally solvent thinned polymer applied 5-10 mils thick

Coating — Generally 90-100% solids polymer with some fillers & pigments applied at 10-50 mils thickness.

Topping — Composition surfacing consisting of coating material and additional aggregate/filler, applied at 50-250 mils thickness, i.e. mortar, slurry, broadcast.

Resin Rich — High polymer/aggregate ratio method of installing composition flooring systems that achieve maximum impermeability and performance characteristics.

1.04 PRODUCTS

A distinction is to be made between individual components or materials used in the flooring system and the composite system assembled to meet a project’s aesthetic and functional requirements. The polymer composition special surfacing system is composed of several materials or components, utilized for specific functions within the system.

1.04.1. SPECIFICATION FOR EPOXY QUARTZ COMPOSITION FLOORING SYSTEM

a. Epoxy composition flooring system shall be a resin rich composite consisting of:

1. Low viscosity clear epoxy primer, for maximum bond potential.

2. 100% solids epoxy mortar underlayment for cracked, spalled or depressed area patching; for sloping & pitching to drains; for forming cove bases; for sealing around drains 100% solids resin rich epoxy mortar matrix layer with high polymer to aggregate ratio for thickness & texture

3. Two 100% solids topcoats for final seal and texture

b. Primer (Subsurface conditions dictate the selection of an appropriate primer. Check one of the following.)

1. Highly polished, dense concrete shall be primed using a water or solvent thinned 30% solids epoxy with chemical coupling agent additive designed to promote chemical bond to bare concrete.

2. Worn, spalled, very porous concrete shall be primed using 100% solids epoxy primer.

3. Bonding to oil saturated concrete, after chemically removing as much contamination as possible and mechanically abrading, shall be enhanced by utilizing a special oil tolerant, 100% solids modified epoxy primer

4.Damp subsurfaces shall be primed for adequate adhesion, when time won’t permit thorough drying, with waterborne or moisture insensitive epoxy primer. This technique must be limited to applications which will not result in encapsulation of moisture in concrete or the creation of negative side hydrostatic force behind the epoxy composition flooring system.

5. Very smooth, non-porous subsurfacing, such as glazed tile, shall be prepared for excellent adhesion by first treating with a ceramic etch compound and then priming with epoxies that contain additional wetting agents and chemical coupling agents.

c. Special Polymer Underlayments

The following special purpose polymer underlayments shall be used as applicable. (Check all that apply.)

__100% solids elastomeric epoxy membrane and underlayment with long term flexibility shall be used to provide waterproofing of small working cracks, and to act as a stress relieving / stress absorbing base coat between substrate and flooring, and to enhance bond potential. 100% solids elastomeric epoxy mortar shall be used for patching, joint nosing repair, for forming wall/floor intersecting coved base radius and for filler around drain housings (see accompanying detail sketches). Polymer to aggregate ratio shall be 1:2 by weight.

__Expansion joint treatment: See accompanying detail sketches.

__Pitching and sloping shall be performed using semi-rigid, 100% solids epoxy combined with graded, high density quartz aggregate with polymer to aggregate ratio of 1 to 4 by weight. At perimeter of the room where thicker section of mortar is required, the polymer to aggregate can be lowered to 1 to 6 and the matrix can be extended with larger, pea gravel aggregate.

__Thin section pitching mortar — from 2 to feather edge — shall be prepared using higher polymer to aggregate ratios with smaller aggregates. See accompanying detail sketches.

NOTE: If the floor surfacing system requires pitching or sloping, first prime the subsurface, do all patching, crack repair, & drain detail work, then install pitching & sloping mortar, then install 100% solids elastomeric epoxy layer, then proceed with the matrix (body) layer

d. Matrix Layer

Matrix layer shall be prepared using semi-rigid, 100% solids, cycloaliphatic amine cured epoxy with standard grade 28 mesh quartz (or colored quartz for multi-color pattern floors). Polymer/aggregate ratio to be 1:2 by volume, which will produce the required impermeable, non-porous surface. For forming vertical surfaces use semi-rigid, 100% solids cycloaliphatic amine cured epoxy and aggregate composition with polymer/aggregate ratio of 1 to 4, or polymer/aggregate ratio of 1 to 3 with thixotropic agent such as fumed silica added to the matrix composition.

e. Topcoats

Use semi-rigid, 100% solids cycloaliphatic amine cured epoxy without aggregates or fillers. Use clear epoxy for multi-colored quartz patterns and use pigmented epoxy in color selected by Owner for solid-colored floors. Note: For rough textures, apply single topcoat 15 mils thick; for smoother textures, apply second topcoat at 10-15 mils thick For areas subjected to constant temperatures greater than 1600F, use 100% solids Novolac epoxy for the topcoat and in the matrix layer. In areas that may require greater chemical resistance, please consult with flooring system installer and manufacturer for assistance in selection of appropriate material for the specific chemical exposure.

1.04.2. PERFORMANCE CRITERIA — COMPOSITE SYSTEM

The typical performance properties listed in Tables 1-4 shall represent the minimum standards for each type of component as listed. Materials which fail to meet all of these criteria will not be acceptable for use.

1.04.3. ACCEPTABLE MANUFACTURER

The following shall be acceptable products and manufacturers, and shall be deemed to conform to the requirements of these specifications:

a. Semi-rigid 100% solids epoxy shall be FLEXI-GARD 500-S as manufactured by Edison Coatings, Inc. Plainville, CT 06704 Phone (800)697-8055.

b. 100% solids Novolac epoxy shall be FLEXI-GARD 500-N as manufactured by Edison Coatings, Inc.

c. 100% solids Flexible modified epoxy shall be FLEXI-DECK 500-E as manufactured by Edison Coatings, Inc.

d. Low temperature 100% solids flexible epoxy shall be FLEXI-DECK 500-U- LT as manufactured by Edison Coatings, Inc.

e. Oil-tolerant, low viscosity epoxy primer shall be FLEXI-DECK 500-L as manufactured by Edison Coatings, Inc.

Table 1. Typical 100% Solids, Semi-Rigid Bisphenol A Epoxy Flooring